Updating Configurations

enaio® webclient 10.10 »

It is usually necessary to restart components that enaio® webclient accesses after making changes to configurations. Users must also reload enaio® webclient in the browser.

enaio® applications

Changes

Necessary actions

enaio® editor

Change to the object definition:

  • Properties of object types

  • Properties of text fields

  • Form design

  • Object type relation

  • Add catalog entries

  • Add languages

  • Import an object definition

Restart the 'dms' microservice.

enaio® editor / 

enaio® administrator

Add new object types and grant access rights.

Restart the 'dms' microservice.

Reload enaio® webclient with F5.

If the technical user is still in use, then the 'osweb' microservice must also be restarted.

enaio® administrator

Change of access rights to existing object types.

Reload enaio® webclient with F5.

If the technical user is still in use, then the 'osweb' microservice must also be restarted.

enaio® administrator

Change/add clauses for access rights.

Changes apply immediately after saving them in enaio® administrator.

enaio® administrator

Change of users' system roles.

Restart enaio® appconnector.

enaio® administrator

Change to the user management:

  • Create new user

  • Create new group

  • Change of users' assignments to groups

Restart enaio® appconnector.

enaio® editor-for-workflow

Change to the workflow organization:

  • Create new user

  • Create new roles

  • Change members of role

  • Change attributes of organization objects

  • Change of user assignment
    – workflow user

Restart enaio® appconnector.

AD synchronizations

Update to the user administration and workflow organization.

Restart enaio® appconnector.

enaio® editor-for-events / 

enaio® editor-for-workflow

Change/add client-side Java Script events.

Reload enaio® webclient with Shift+F5

enaio® webclient Service Release

Import Service Release of enaio® webclient.

Restart the 'osweb' microservice.

Reload enaio® webclient with Shift+F5.