enaio® start

enaio® 11.0 »

enaio® start starts the automatic actions which have been scheduled for execution. The actions themselves cannot be edited in enaio® start.

Actions that are configured to be performed in Cyclic mode will be run for the first time shortly after the launch of enaio® start. They will then be run again after the specified period has expired. If you close enaio® start, no data regarding the cycles of automatic actions will be saved. Right after enaio® startis launched the next time, all cyclical actions will be run again.

The enaio® start program (axauto.exe) is found in the administration components directory.

enaio® start requires administrator rights. When it is started for the first time, it must be started manually from the application directory. You will also need to enter a user name and a password. The data is saved in the registry. This user is then designated to launch the program. The 'Server: Switch job context' system role is required for the user.
If you want to change the user, delete the following key and then restart enaio® start:
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\OPTIMALSYSTEMS\AsAuto

When launching enaio® start, a window will open which lists all actions for which execution times have been specified.

Actions are placed in a queue if other actions are also processed at the defined start time.

Logging data of running actions is displayed in the lower area of the window. The log is automatically written to the file osDDMMYY.prt. DDMMYY represents the date. The log files are saved to the configured log directory. You can open old logs using the Log button.

The logs will not be deleted automatically. At regular intervals, you will have to manually remove logs which are no longer needed.

Independent of this logging process, the enaio® logging takes place according to the settings in the oxrpt.cfg configuration file. With respect to this logging process you can set up the logging level of the flow channel for the duration of a session. The change to the logging depth will be applied immediately; enaio® start does not have to be restarted.

Click the Log settings entry in the context menu of the title bar to open the dialog.

The Send configuration button is used to send the active logging configuration oxrpt.cfg by e-mail. When doing so, all log files (*.evn) of the current day and the configuration file will be sent as a ZIP archive.

Users with the 'Administrator: Configure entire system' system role can permanently apply the logging level settings.

You can close enaio® start using the End button. Any action which is still running will be completed. Actions in the queue will not be executed.

Error Return Values for Actions

If you add the parameter '/X' to the generated start parameters for enaio® start, the value '0' is not returned every time in the event of an error; instead, a value is returned for the action during which the error occurred. This allows the relevant action to be identified in a series of actions.

Action

Internal error value

Hexadecimal error value

Decimal error value

Error level in command.exe

UNKNOWN

1019

0x800703FB

2147943419

-2147023877

AXACARCH

1020

0x800703FC

2147943420

-2147023876

AXACEXP

1021

0x800703FD

2147943421

-2147023875

AXACIMP

1022

0x800703FE

2147943422

-2147023874

AXACSYNC

1023

0x800703FF

2147943423

-2147023873

AXACABO

1024

0x80070400

2147943424

-2147023872

AXACHIST

1025

0x80070401

2147943425

-2147023871

AXACWDVL

1026

0x80070402

2147943426

-2147023870

AXACSCRIPT

1027

0x80070403

2147943427

-2147023869

AXACPAGE

1028

0x80070404

2147943428

-2147023868

AXACPREF

1029

0x80070405

2147943429

-2147023867

AXACREQ

1030

0x80070406

2147943430

-2147023866

AXACUNAC

1031

0x80070407

2147943431

-2147023865

AXACDOK2TIF

1032

0x80070408

2147943432

-2147023864

AXACMTIF

1033

0x80070409

2147943433

-2147023863

AXACLTRASH

1034

0x8007040A

2147943434

-2147023862

AXACHASH

1035

0x8007040B

2147943435

-2147023861

AXACSIGN

1036

0x8007040C

2147943436

-2147023860

AXACPDFA

1037

0x8007040D

2147943437

-2147023859

AXACDEL

1038

0x8007040E

2147943438

-2147023858

AXACCOM

1039

0x8007040F

2147943439

-2147023857

AXACEXEC

1040

0x80070410

2147943440

-2147023856

AXACUNME

1042

0x80070412

2147943442

-2147023854

AXACTARC

1043

0x80070413

2147943443

-2147023853

AXACADJR

1044

0x80070414

2147943444

-2147023852

AXACCRYPT

1045

0x80070415

2147943445

-2147023851

AXACIDX

1046

0x80070416

2147943446

-2147023850

AXACVCEXP

1047

0x80070417

2147943447

-2147023849

AXACSUMM

1048

0x80070418

2147943448

-2147023848

AXACCVGEN

1049

0x80070419

2147943449

-2147023847

AXACDBST

1050

0x8007041A

2147943450

-2147023846

AXACCL

1051

0x8007041B

2147943451

-2147023845

AXACWFHCLEAR

1052

0x8007041C

2147943452

-2147023844

AXACSYSC

1053

0x8007041D

2147943453

-2147023843

AXAOLFR

1054

0x8007041E

2147943454

-2147023842

AXACHASHD

1055

0x8007041F

2147943455

-2147023841

AXACDCM

1059

0x80070422

2147943458

-2147023838

AXACXMLE

1060

0x80070423

2147943459

-2147023837

AXACXMLC

1061

0x80070424

2147943460

-2147023836